{"product_id":"impro-itrt2-distributed-controller-pc-board-only","title":"Impro iTRT2 Distributed Controller PC Board only","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eImpro iTRT2 Distributed Controller PC Board only\u003c\/h2\u003e\n\u003cp\u003eiTRT2 Distributed Controller PC Board only.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile: variants for indoor and outdoor use\u003c\/li\u003e\n\u003cli\u003eCompatibility: support for OSDP and legacy Wiegand readers\u003c\/li\u003e\n\u003cli\u003eSimplicity: available in 3 variants for ease of installation options\u003c\/li\u003e\n\u003cli\u003eInteroperability: compatible and integrated with Impro solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003eSpecifications\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHCD900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eiTRT2 in plastic housing (No PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (D x W x H)\u003c\/td\u003e\n\u003ctd\u003e164mm x 140mm x 28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Product Weight\u003c\/td\u003e\n\u003ctd\u003e0.35kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePC Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements at 12VDC\u003c\/td\u003e\n\u003ctd\u003e120mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Power Requirements\u003c\/td\u003e\n\u003ctd\u003e0.45W per relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input Protection\u003c\/td\u003e\n\u003ctd\u003eReverse polarity and over-current protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-485 Ports\u003c\/td\u003e\n\u003ctd\u003e1 x 38400 RS-485 for controller networking 1 x 38400 RS-485 for Aperio™ lock hubs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOSDP \u0026amp; Wiegand\u003c\/td\u003e\n\u003ctd\u003e2 hardware-selectable ports for OSDP or legacy Wiegand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd\u003e20 Status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e2 x Door Open Sensor inputs 2 x Request to Exit Button inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e4 dry contact inputs with end-of-line (EOL) sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Relay Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e3 x independent, SPDT dry contact relays (NO, COM, NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay contacts\u003c\/td\u003e\n\u003ctd\u003eNormally Open, Common, Normally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Ratings\u003c\/td\u003e\n\u003ctd\u003e5A @ 28VDC (TV-5 Rated), 100k operations minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C (-13°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +176°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95% RH non-condensing (at +40°C \/ +104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSABS Certification (RSA)\u003c\/td\u003e\n\u003ctd\u003e✔️\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersatility\u003c\/td\u003e\n\u003ctd\u003eVariants for indoor and outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSupports OSDP and legacy Wiegand readers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimplicity\u003c\/td\u003e\n\u003ctd\u003eAvailable in 3 variants for ease of installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInteroperability\u003c\/td\u003e\n\u003ctd\u003eCompatible and integrated with Impro solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Specifications\u003c\/td\u003e\n\u003ctd\u003ePart Number: HCD900 Product Description: iTRT2 in plastic housing (No PSU) Colour: Grey Dimensions (D × W × H): 164 mm × 140 mm × 28 mm Approx. Product Weight: 0.35 kg Material: PC Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Specifications Input Voltage\u003c\/td\u003e\n\u003ctd\u003e12â€¯V DC Power Requirements at 12â€¯V DC: 120â€¯mA Relay Power Requirements: 0.45â€¯W per relay Power Input Protection: Reverse polarity and over-current protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnectivity Ethernet\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-T RS-485 Ports: 1 × 38400 RS-485 for controller networking, 1 × 38400 RS-485 for Aperio™ lock hubs OSDP \u0026amp; Wiegand: 2 hardware-selectable ports for OSDP or legacy Wiegand Status LEDs: 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Specification Digital Inputs\u003c\/td\u003e\n\u003ctd\u003e2 × Door Open Sensor inputs, 2 × Request to Exit Button inputs Input Type: 4 dry contact inputs with end-of-line (EOL) sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e HCD900-0-0-GB-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Impro\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Impro","offers":[{"title":"Default Title","offer_id":67696202875109,"sku":"HCD900-0-0-GB-00","price":6134.0,"currency_code":"ZAR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/0010\/6725\/files\/Impro-iTRT2-Distributed-Controller.jpg?v=1791982714","url":"https:\/\/guardsondutyshop.co.za\/products\/impro-itrt2-distributed-controller-pc-board-only","provider":"Guards On Duty Shop \u0026 Security Guards ","version":"1.0","type":"link"}